Programa del congreso
Resúmenes y datos de las sesiones para este congreso. Seleccione una fecha o ubicación para mostrar solo las sesiones en ese día o ubicación. Seleccione una sola sesión para obtener una vista detallada (con resúmenes y descargas, si están disponibles).
Tenga en cuenta que todos los horarios se muestran en la zona horaria del congreso. La hora actual del congreso es: 24/08/2026 05:33:44 America, Santiago
|
Resumen diario |
| Sesión | |
|
72F: Energy & Water Lugar: Room 09: Luz | |
| Presentación 1 | |
11:00 - 11:12
Comparative Evaluation of University Drinking Fountain Technology and Its Influence on the Physicochemical and Microbiological Water Quality 1: Departamento de Ingeniería Civil y Ambiental, Universidad de Ingeniería y Tecnología (UTEC) - Lima, Perú; 2: Centro de Investigación y Tecnología del Agua (CITA), Universidad de Ingeniería y Tecnología (UTEC) - Lima, Perú Access to safe drinking water is a fundamental human right and crucial need for human health. On university campuses, drinking fountains are essential to provide safe drinking water, promote healthy habits, and reduce the use of plastic bottles among the university community. This research evaluated four university drinking fountains in Lima, Peru to understand how their technical design influences the physical–chemical and microbiological quality of the water they provide. Samples from the fountains underwent water quality analyse, based on internationally applied Standard Methods (Standard Methods for the Examination of Water and Wastewater), for pH, alkalinity, hardness, conductivity, chloride, sodium, free ammonia, nitrate, (residual) free chlorine and microbial contamination. In addition, water quality results were compared to the Peruvian regulatory limits for drinking water (Decreto Supremo N.° 031-2010-SA). All samples met microbiological standards and regulatory limits for most water quality parameters. However, free chlorine levels were consistently below recommended levels and one fountain sample had very high hardness. By correlating water quality data with the presence of filters, dispensing mechanisms and hygienic design features, we demonstrate that fountains equipped with certified filters and hands‑free operation maintain more stable water chemistry, whereas those lacking filtration or maintenance exhibit greater variability. The findings underscore the importance of considering drinking fountains as technological systems whose performance affects water quality, and the need for continuous monitoring and proactive maintenance at the point of consumption. | |
